Cardiology 2013 (Full reference info)

Reference Type: Journal Article
Record Number: 825Author: Antic, V., Ciraj-Bjelac, O., Rehani, M., Aleksandric, S., Arandjic, D. and Ostojic, M.
Year: 2013
Title: Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
Journal: Radiat Prot Dosimetry
Volume: 154
Issue: 3
Pages: 276-84
Short Title: Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
Alternate Journal: Radiation protection dosimetry
ISSN: 1742-3406 (Electronic)
0144-8420 (Linking)
DOI: 10.1093/rpd/ncs236
Accession Number: 23152146
Keywords: Angiography/*statistics & numerical data
Humans
Lens, Crystalline/*physiology/radiation effects
Medical Staff, Hospital/*statistics & numerical data
Occupational Exposure/analysis/*statistics & numerical data
*Radiation Dosage
Radiation Monitoring/instrumentation/*statistics & numerical data
Radiography, Interventional/*statistics & numerical data
Risk Assessment
Serbia
Abstract: Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 microSv for the first operator, 33 microSv for the second operator/nurse and 12 microSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 microSv Gy(-)(1) cm(-)(2) for the first operator, 0.33 microSv Gy(-)(1) cm(-)(2) for the second operator/nurse and 0.16 microSv Gy(-)(1) cm(-)(2) for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values.
Notes: Antic, V
Ciraj-Bjelac, O
Rehani, M
Aleksandric, S
Arandjic, D
Ostojic, M
eng
Multicenter Study
Research Support, Non-U.S. Gov’t
England
2012/11/16 06:00
Radiat Prot Dosimetry. 2013;154(3):276-84. doi: 10.1093/rpd/ncs236. Epub 2012 Nov 14.
URL: http://www.ncbi.nlm.nih.gov/pubmed/23152146
Author Address: Center for Nuclear Medicine, University Clinical Centre of Serbia, Belgrade, Serbia.

Pages: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155